Heating powers

1740 – 15600 W

Cooling powers

1300 – 12600 W

6 types

Galletti

 
FC/NL

PARIETAL, DIAGONAL AIR BLOW

 
FC/NA

PARIETAL, VERTICAL AIR BLOW

 
FC/NB

FLOOR, VERTICAL AIR BLOW

 
FC/NIP

PARIETAL, TO BE COVERED

 
FC/NS

CEILING


 
FC/NIS

CEILING, TO BE COVERED


Type FC/N
-1 -1A -2 -2A -3 -3A -4 -4A -6 -6A -8 -8A -10 -10A -12 -12A
Total cooling power (1) (E) W
Frig/h
1290
1110
1750
1506
1945
1674
2170
1867
2840
2444
3120
2685
3810
3278
4220
3803
4840
4165
5390
4638
6175
5314
7235
6226
7695
6622
8345
7181
10715
9220
12600
10780
Operational cooling power (1) (E) W
Frig/h
1010
869
1205
1037
1480
1274
1290
1110
2120
1824
2160
1859
2865
2465
3065
2637
3680
3167
3815
3283
4660
4010
5045
4341
5840
5025
5985
5150
8070
6944
9325
8024
Water flow (E) l/s 0,0615 0,0834 0,0927 0,103 0,135 0,135 0,182 0,211 0,231 0,257 0,294 0,344 0,367 0,398 0,511 0,598
Flow’s loss (E) kPa 6,83 10,93 9,49 15,92 8,03 13,09 7,62 13,66 11,60 19,33 8,50 15,43 12,50 13,10 15,60 20,60
Heating power (2) (E) W
Kcal/h
1740
1497
2055
1768
2505
2155
2635
2267
3570
3072
3680
3167
4880
4200
5230
4500
6230
5360
6550
5636
7880
6772
8615
7413
9880
8502
10345
8902
13320
11462
15600
13424
Water flow (E) l/s 0,0615 0,0834 0,0927 0,103 0,135 0,149 0,182 0,211 0,231 0,257 0,294 0,344 0,367 0,398 0,511 0,598
Flow’s loss (E) kPa 5,90 9,36 8,14 13,58 6,87 11,18 6,52 11,64 9,89 16,49 7,28 13,16 10,70 11,21 13,30 17,60
Heating power (3)   W
Kcal/h
2965
2551
3450
2969
4280
3683
4430
3812
6025
5185
6175
5313
8170
7030
8745
7525
10580
9104
11015
9478
13375
11509
14435
12421
16795
14452
17445
15011
22540
19396
26350
22674
Water flow   l/s 0,072 0,084 0,104 0,108 0,146 0,150 0,199 0,213 0,257 0,268 0,325 0,351 0,408 0,425 0,548 0,641
Flow’s loss   kPa 7,47 8,72 9,60 13,50 7,64 10,54 7,37 10,99 10,60 16,46 8,38 12,61 12,50 11,59 14,69 19,22
Heating power for DF type (3)   W
Kcal/h
1860
1600
1860
1600
2440
2100
2440
2100
3610
3100
3610
3100
4650
4000
4650
4000
5930
5100
5930
5100
7910
6800
7910
6800
10000
8600
10000
8600
10470
9000
11630
10000
Water flow   l/s 0,044 0,044 0,058 0,058 0,086 0,086 0,111 0,111 0,142 0,142 0,189 0,189 0,239 0,239 0,250 0,278
Flow’s loss   kPa 3,45 3,45 5,29 5,29 13,92 13,92 7,45 7,45 10,98 10,98 21,86 21,86 31,96 31,96 46,65 55,33
Water capacity of exchanger   l 0,60 0,90 0,90 1,20 1,30 1,73 1,75 2,30 1,75 2,30 2,60 3,36 2,60 3,46 3,20 3,20
Water capacity of DF exchanger   l 0,25 0,25 0,25 0,25 0,35 0,35 0,50 0,50 0,50 0,50 0,75 0,75 0,75 0,75 0,90 0,90
Maximum operating pressure   bar 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
Tentative pressure   bar 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Terminals     1/2" 3/4"
Air productivity max.
mid.
min.
l/s
l/s
l/s
69,4
51,4
37,5
68,0
50,4
36,8
88,9
66,7
48,6
87,1
65,4
47,6
125,0
93,1
68,1
122,5
91,2
66,7
172,2
129,2
94,4
168,8
126,6
92,5
222,2
166,7
122,2
217,8
163,4
119,8
291,7
218,1
159,7
285,9
213,7
156,5
361,1
270,8
198,16
353,9
265,4
194,6
472,2
354,2
259,7
555,6
416,7
305,6
Air speed max. m/s 0,812 0,796 1,040 1,019 0,906 0,888 0,904 0,886 1,166 1,143 1,000 0,980 1,238 1,213 1,332 1,567
Voltage of power supply   V-f-Hz 220-1-50
Intensity (E) max.
mid.
min.
A
A
A
0,173
0,114
0,087
0,173
0,114
0,087
0,251
0,166
0,103
0,251
0,166
0,103
0,264
0,193
0,131
0,264
0,193
0,131
0,377
0,256
0,172
0,377
0,256
0,172
0,489
0,357
0,245
0,489
0,357
0,245
0,798
0,574
0,397
0,798
0,574
0,397
1,097
0,771
0,536
1,097
0,771
0,536
1,336
1,120
0,874
1,766
1,361
1,071
Power (E) max.
mid.
min.
W
W
W
37
25
19
37
25
19
55
36
22
55
36
22
58
42
28
58
42
28
82
54
35
82
54
35
107
77
52
107
77
52
185
124
84
185
124
84
235
161
108
235
161
108
274
223
170
380
273
212
Volume (E) max.
mid.
min.
dB/A
dB/A
dB/A
43
36
29
43
36
29
46
39
29
46
39
29
47
40
31
47
40
31
49
42
34
49
42
34
55
49
39
55
49
39
59
53
45
59
53
45
65
57
48
65
57
48
66
61
55
70
64
57
Hum pressure max.
mid.
min.
dB/A
dB/A
dB/A
35-38
28-31
21-24
35-38
28-31
21-24
38-41
31-34
21-24
38-41
31-34
21-24
39-42
32-35
23-26
39-42
32-35
23-26
41-44
34-37
26-29
41-44
34-37
26-29
47-50
41-44
31-34
47-50
41-44
31-34
51-54
45-48
37-40
51-54
45-48
37-40
57-60
49-52
40-43
57-60
49-52
40-43
58-61
53-56
47-50
62-65
56-59
49-52
Weight (including casing) kg 23,3 23,8 23,5 23,8 28,6 28,8 34,5 35,9 35,4 36,0 45,0 47,6 45,5 46,8 47,0 56,5
Weight (without casing) kg 15,9 15,9 16,5 16,7 21,3 22,0 26,0 26,8 26,2 27,0 35,5 35,1 36,0 39,0 40,0 41,0
Corrective factors                                    
Total cooling power (1) mid.
min.
  0,81
0,65
0,76
0,58
0,79
0,56
0,77
0,53
0,84
0,63
0,82
0,60
0,77
0,58
0,74
0,54
0,82
0,65
0,81
0,62
0,82
0,63
0,79
0,59
0,81
0,58
0,80
0,56
0,77
0,54
0,76
0,55
Operational cooling power (1) mid.
min.
  0,79
0,62
0,75
0,57
0,77
0,53
0,76
0,51
0,83
0,61
0,81
0,58
0,75
0,56
0,73
0,52
0,81
0,62
0,79
0,60
0,80
0,60
0,78
0,57
0,80
0,55
0,78
0,53
0,74
0,51
0,73
0,52
Heating power (3) mid.
min.
  0,79
0,62
0,73
0,55
0,78
0,53
0,74
0,48
0,83
0,59
0,80
0,56
0,76
0,56
0,71
0,50
0,81
0,62
0,79
0,58
0,81
0,60
0,77
0,54
0,80
0,55
0,78
0,51
0,77
0,54
0,75
0,54
Heating power with DF exchanger mid.
min.
  0,91
0,82
0,91
0,82
0,89
0,82
0,89
0,82
0,87
0,73
0,87
0,73
0,83
0,84
0,83
0,84
0,86
0,73
0,86
0,73
0,88
0,75
0,88
0,75
0,84
0,73
0,84
0,73
0,84
0,71
0,84
0,71

Values marked with (E) symbol relate to ventilo-convectors which have the letter A at the end. Standard powers are given for the maximum speed of a ventilator and following conditions:

(1) in a cooling mode

  • entering water temperature 7°C
  • returning water temperature 12°C
  • entering air temperature 27°

(2) in a heating mode

  • Water temperature (admission) 50°C
  • Water temperature (as in cooling) 12°C
  • Entering air temperature 20°C

(3) in a heating mode

  • Water temperature (admission) 70°C
  • returning water temperature 50°C
  • Entering air temperature 20°C
ce.gif (1874 bytes)